English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 45346/58522 (77%)
造訪人次 : 2506100      線上人數 : 201
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: http://libir.tmu.edu.tw/handle/987654321/44515


    題名: Surgical treatment of unstable subtrochanteric fracture with dynamic condylar screw
    以動態髁螺釘治療不穩定股骨轉子下骨折
    作者: 林心畬;莊太元;廖宜賢;王普光;吳柏林;何為斌
    貢獻者: 生化學科
    日期: 2009
    上傳時間: 2011-10-13 19:15:48 (UTC+8)
    摘要: 【Introduction】
    The management of unstable subtrochanteric fracture is challenging to each
    orthopaedic surgeon. There was a controversy over the choice of implants
    between intra-medullary or extra-medullary devices. This topic presented our
    prospective series with unstable subtrochanteric fractures treated with
    dynamic condylar screws (DCS).
    【Materials and Methods】
    From 2003 through 2008, 118 peritrochanteric fractures were treated
    surgically by one surgeon. Twenty of them using DCS under indication of
    Seinsheimer classification (for subtrochanteric fractures) type IIC, III, IV, and
    V . Fracture union by serial X-ray evaluation was made monthly, and change
    of neck-shaft angle and medial migration were also estimated. Functional
    tests with Harris hip score were also evaluated.
    【Results】
    Eighteen of the 20 patients were followed for an average of 35.1 months
    (range 8-58 months). Functional outcome was excellent (>90 points) in 13
    (13/18), good (80-99 points) in 2 (2/18), and fair (70-79 points) in 3(3/18).
    The primary union rate was 94% (17/18) in 12 weeks, and implants failure
    rate was 6% (1/18) which received revised surgery. Superficial wound
    infection was noted in one case.
    【Discussion】
    Unstable subtrochanteric fractures are difficult to treat due to high
    compression and tension force in the medial cortex with high failure rate of
    internal fixation. The most common devices for internal fixation include
    intra-medullar nail (IM nail), trochanteric stabilized plate (THS), and DCS.
    Dynamic hip screw had obviously higher failure rate and wasn't suggested in
    such fracture type. Although IM nail showed better then DCS in
    biomechanical studies, literature review showed great variation of results,
    and no large randomized control trial comparing available. There is some
    limitation of IM nail, including severe comminuting with intertrochanteric
    顯示於類別:[骨科] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在TMUIR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    著作權聲明 Copyright Notice
    • 本平台之數位內容為臺北醫學大學所收錄之機構典藏,包含體系內各式學術著作及學術產出。秉持開放取用的精神,提供使用者進行資料檢索、下載與取用,惟仍請適度、合理地於合法範圍內使用本平台之內容,以尊重著作權人之權益。商業上之利用,請先取得著作權人之授權。

      The digital content on this platform is part of the Taipei Medical University Institutional Repository, featuring various academic works and outputs from the institution. It offers free access to academic research and public education for non-commercial use. Please use the content appropriately and within legal boundaries to respect copyright owners' rights. For commercial use, please obtain prior authorization from the copyright owner.

    • 瀏覽或使用本平台,視同使用者已完全接受並瞭解聲明中所有規範、中華民國相關法規、一切國際網路規定及使用慣例,並不得為任何不法目的使用TMUIR。

      By utilising the platform, users are deemed to have fully accepted and understood all the regulations set out in the statement, relevant laws of the Republic of China, all international internet regulations, and usage conventions. Furthermore, users must not use TMUIR for any illegal purposes.

    • 本平台盡力防止侵害著作權人之權益。若發現本平台之數位內容有侵害著作權人權益情事者,煩請權利人通知本平台維護人員([email protected]),將立即採取移除該數位著作等補救措施。

      TMUIR is made to protect the interests of copyright owners. If you believe that any material on the website infringes copyright, please contact our staff([email protected]). We will remove the work from the repository.

    Back to Top
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋