    題名: Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface
    作者: 何昭德
    貢獻者: 醫學系眼科學科
    日期: 2009
    上傳時間: 2009-08-07 15:50:04 (UTC+8)
    摘要: Abstract
    PURPOSE: To evaluate the accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement.

    DESIGN: Prospective, observational study.

    METHODS: The right eyes of 493 subjects were measured with a rotating Scheimpflug camera (Pentacam; Oculus, Wetzlar, Germany). The keratometric corneal astigmatism (KA) was obtained by using the anterior corneal surface measurement and the keratometric index (1.3375) while neglecting the posterior corneal surface measurement. The Pentacam-derived total corneal astigmatism (PA) was derived by doubled-angle vector analysis of the astigmatisms on both corneal surfaces.

    RESULTS: The mean arithmetic and absolute estimation errors of the KA magnitude for the PA magnitude were -0.06 +/- 0.28 diopters (D) (range, -0.59 to 0.91 D) and 0.24 +/- 0.16 D (range, 0 to 0.91 D), respectively. The mean arithmetic and absolute estimation errors of the KA angle for the PA angle were -0.6 degrees +/- 12.7 degrees (range, -69.9 degrees to 83.4 degrees) and 7.4 degrees +/- 10.3 degrees (range, 0 degrees to 83.4 degrees), respectively. Among all eyes, 142 eyes (28.8%) had either a KA magnitude that differed by > 0.50 D from the PA magnitude or a KA angle that differed by > 10 degrees from the PA angle. For the 282 eyes with a KA magnitude exceeding 1.0 D (that are candidates for intraoperative correction of a preexisting astigmatism during cataract surgery), 29 eyes (10.3%) had either a KA magnitude that differed by > 0.50 D from the PA magnitude or a KA angle that differed by > 10 degrees from the PA angle.

    CONCLUSIONS: Neglecting the posterior corneal surface measurement may lead to significant deviation in the corneal astigmatism estimation in a proportion of eyes.
    關聯: American Journal of Ophthalmology 147:788-795
    資料類型: article
    顯示於類別:[眼科學科] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    150.pdf1066KbAdobe PDF310檢視/開啟
    全文.txt0KbText366檢視/開啟
    摘要.pdf57KbAdobe PDF178檢視/開啟


    在TMUIR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    著作權聲明 Copyright Notice
    • 本平台之數位內容為臺北醫學大學所收錄之機構典藏,包含體系內各式學術著作及學術產出。秉持開放取用的精神,提供使用者進行資料檢索、下載與取用,惟仍請適度、合理地於合法範圍內使用本平台之內容,以尊重著作權人之權益。商業上之利用,請先取得著作權人之授權。

      The digital content on this platform is part of the Taipei Medical University Institutional Repository, featuring various academic works and outputs from the institution. It offers free access to academic research and public education for non-commercial use. Please use the content appropriately and within legal boundaries to respect copyright owners' rights. For commercial use, please obtain prior authorization from the copyright owner.

    • 瀏覽或使用本平台,視同使用者已完全接受並瞭解聲明中所有規範、中華民國相關法規、一切國際網路規定及使用慣例,並不得為任何不法目的使用TMUIR。

      By utilising the platform, users are deemed to have fully accepted and understood all the regulations set out in the statement, relevant laws of the Republic of China, all international internet regulations, and usage conventions. Furthermore, users must not use TMUIR for any illegal purposes.

    • 本平台盡力防止侵害著作權人之權益。若發現本平台之數位內容有侵害著作權人權益情事者,煩請權利人通知本平台維護人員([email protected]),將立即採取移除該數位著作等補救措施。

      TMUIR is made to protect the interests of copyright owners. If you believe that any material on the website infringes copyright, please contact our staff([email protected]). We will remove the work from the repository.

    Back to Top
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋